TUNCMATIK NEWTECH PRO 2KVA RACK- MOUNT 1/1 ON-LINE UPSLCD/TSK1812



1817.66 GEL
ხელმისაწვდომია

TUNCMATIK NEWTECH PRO 2KVA RACK- MOUNT 1/1 ON-LINE UPSLCD/TSK1812 / 4486

General Properties
Product CodeTSK1812
EAN Code8697842802323
Series descriptionNewtech Pro Rack
Product descriptionNewtech Pro Rack 2 kVA
Capacity / Power2 kVA / 1600 W
DisplayLCD Panel
AlarmBattery mode, Low battery, Over load, Error
Input
Low voltage transfer160 VAC - %80-100, 140VAC - %70-80, 120 VAC - %60-70, 110 VAC - %0-60
Low voltage correction170 VAC - %80-100, 150VAC - %70-80, 130 VAC - %60-70, 120 VAC - %0-60
High voltage transfer300 VAC ± %5
High voltage correction290 VAC ± %5
Frequency range40 - 70 Hz
Phase1 Phase + Notr + PE
Power factor≥ 0.99 %100 load
Output
Output voltage200/208/220/230/240 VAC
Output power factor (PF)0.8
Voltage regulation battery mode± %1
Frequency range sync. mode47-53 Hz or 57-63 Hz
Frequency range battery mode50 ± 0.25 Hz - 60 ± 0.3 Hz
Over load line mode%105-110 overload alarm, %110-130 transfer to by-pass in 30sec, %130-150 transfer to by-pass in 1,5sec
Over load battery mode%105-110 overload alarm, %110-130 shuts down in 30sec, %130-150 shuts down in 1,5sec
Current crest ratio3/1 max.
Harmonic distortion≤ %2 THD (Lineer load ) ≤ %8 THD (non-Lineer load)
Transfer time Line ↔ battery0 ms
Transfer time Inverter ↔ by-pass4 ms (tipik)
Waveform (Battery mode)Pure sinewave
Efficiency
Line mode~ %86
Battery mode~ %85
Battery
Type & number of battery12V 9Ah x 4
Charge time5 hours for recharging up to 90% capacity
Charge current1.0 A
Charge voltage54.8 VDC ± %1
Indicators & Alarm
LCD PanelUPS status, Load level, Battery level, Input/Output voltage, Discharge timer, Fault conditions
AlarmBattery mode, Low battery, Overload, Fault
Dimensions & Weight
D x W x H (mm)515 x 440 x 89 [2U]
Net weight (kg)20.6
Environmental
Operating temperature0-40°C
Humidity20-90% RH (non-condensing)
Noise level (audible)< 50 dBA, from 1 m
Management
Smart RS-232 or USBWindows¨ 98/2000/2003/XP/Vista/2008, Windows¨ 7/8, Linux, MAC
SNMP (Optional)Power management from SNMP manager and web browser

TUNCMATIK NEWTECH PRO 2KVA RACK- MOUNT 1/1 ON-LINE UPSLCD/TSK1812
General Properties
Product CodeTSK1812
EAN Code8697842802330
Series descriptionNewtech Pro Rack
Product descriptionNewtech Pro Rack 1 kVA
Capacity / Power3 kVA / 2400 W
DisplayLCD Panel
AlarmBattery mode, Low battery, Over load, Error
Input
Low voltage transfer160 VAC - %80-100, 140VAC - %70-80, 120 VAC - %60-70, 110 VAC - %0-60
Low voltage correction170 VAC - %80-100, 150VAC - %70-80, 130 VAC - %60-70, 120 VAC - %0-60
High voltage transfer300 VAC ± %5
High voltage correction290 VAC ± %5
Frequency range40 - 70 Hz
Phase1 Phase + Notr + PE
Power factor≥ 0.99 %100 load
Output
Output voltage200/208/220/230/240 VAC
Output power factor (PF)0.8
Voltage regulation battery mode± %1
Frequency range sync. mode47-53 Hz or 57-63 Hz
Frequency range battery mode50 ± 0.25 Hz - 60 ± 0.3 Hz
Over load line mode%105-110 overload alarm, %110-130 transfer to by-pass in 30sec, %130-150 transfer to by-pass in 1,5sec
Over load battery mode%105-110 overload alarm, %110-130 shuts down in 30sec, %130-150 shuts down in 1,5sec
Current crest ratio3/1 max.
Harmonic distortion≤ %2 THD (Lineer load ) ≤ %8 THD (non-Lineer load)
Transfer time Line ↔ battery0 ms
Transfer time Inverter ↔ by-pass4 ms (tipik)
Waveform (Battery mode)Pure sinewave
Efficiency
Line mode~ %88
Battery mode~ %86
Battery
Type & number of battery12V 9Ah x 6
Charge time5 hours for recharging up to 90% capacity
Charge current1.0 A
Charge voltage82.1 VDC ± %1
Indicators & Alarm
LCD PanelUPS status, Load level, Battery level, Input/Output voltage, Discharge timer, Fault conditions
AlarmBattery mode, Low battery, Overload, Fault
Dimensions & Weight
D x W x H (mm)635 x 440 x 89 [2U]
Net weight (kg)29
Environmental
Operating temperature0-40°C
Humidity20-90% RH (non-condensing)
Noise level (audible)< 50 dBA, from 1 m
Management
Smart RS-232 or USBWindows¨ 98/2000/2003/XP/Vista/2008, Windows¨ 7/8, Linux, MAC
SNMP (Optional)Power management from SNMP manager and web browser