Tel: 2997712; 2998696;
Under Construction
მულტიმედია და ბიზნეს კომპიუტერები
ხარისხი, გამოცდილება, პროფესიონალიზმი
Filter
ბრანდები
დალაგება: 
რაოდენობა: 
ხედვა: 

General Properties Product Code TSK1815 EAN Code 8697842802354 Series description Newtech Pro Rack Product description Newtech Pro Rack 10 kVA Capacity / Power 10 kVA / 8000 W Display LCD Panel Alarm Battery mode, Low battery, Over load, Error Input Low voltage transfer 176 VAC - %100 load, 110 VAC - %50 load Low voltage correction 186 VAC - %100 load, 120 VAC - %50 load High voltage transfer 300 VAC ± %5 High voltage correction 290 VAC ± %5 Frequency range 40 - 70 Hz Phase 1 Phase + Notr + PE Power factor ≥ 0.99 %100 load Output Output voltage 200/208/220/230/240 VAC Output power factor (PF) 0.8 Voltage regulation battery mode ± %1 Frequency range (Synchronized) 50 Hz Frequency range (Battery mode) 50 Hz ± 0.2 Hz or 60 Hz ± 0.2 Hz Over load line mode %105-110 overload alarm, %110-130 transfer to by-pass in 30sec, %130-150 transfer to by-pass in 1,5sec Over load battery mode %105-110 overload alarm, %110-130 shuts down in 30sec, %130-150 shuts down in 1,5sec Current crest ratio 3/1 max. Harmonic distortion ≤ %3 THD (Lineer load ) ≤ %6 THD (non-Lineer load) Transfer time Line ↔ battery 0 ms Transfer time Inverter ↔ by-pass 4 ms (tipik) Waveform (Battery mode) Pure sinewave Efficiency Line mode ~ %89 Battery mode ~ %88 Battery Type & number of battery 12V 9Ah x 20 Charge time 5 hours for recharging up to 90% capacity Charge current 1.0 A Charge voltage 273 VDC ± %1 Indicators & Alarm LCD Panel UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, Fault conditions Alarm Battery mode, Low battery, Overload, Fault Dimensions & Weight D x W x H (mm) UPS.668 x 438 x 133 [3U] Battery module.668 x 438 x 133 [3U] Net weight (kg) UPS.20kg Battery module.63kg Environmental Operating temperature 0-40°C Humidity 20-90% RH (non-condensing) Noise level (audible) < 55 dBA, from 1 m Management Smart RS-232 or USB Windows¨ 98/2000/2003/XP/Vista/2008, Windows¨ 7/8, Linux, MAC SNMP (Optional) Power management from SNMP manager and web browser

TUNCMATIK Newtech Pro Rack Mount Series 10KVA 1/1 Online IPS TSK1815/Rack Mount UPS
GEL 3329
Limited: Call!
<383>

General Properties Product Code TSK1814 EAN Code 8697842802347 Series description Newtech Pro Rack Product description Newtech Pro Rack 6 kVA Capacity / Power 6 kVA / 4800 W Display LCD Panel Alarm Battery mode, Low battery, Over load, Error Input Low voltage transfer 176 VAC - %100 load, 110 VAC - %50 load Low voltage correction 186 VAC - %100 load, 120 VAC - %50 load High voltage transfer 300 VAC ± %5 High voltage correction 290 VAC ± %5 Frequency range 40 - 70 Hz Phase 1 Phase + Notr + PE Power factor ≥ 0.99 %100 load Output Output voltage 200/208/220/230/240 VAC Output power factor (PF) 0.8 Voltage regulation battery mode ± %1 Frequency range (Synchronized) 50 Hz Frequency range (Battery mode) 50 Hz ± 0.2 Hz or 60 Hz ± 0.2 Hz Over load line mode %105-110 overload alarm, %110-130 transfer to by-pass in 30sec, %130-150 transfer to by-pass in 1,5sec Over load battery mode %105-110 overload alarm, %110-130 shuts down in 30sec, %130-150 shuts down in 1,5sec Current crest ratio 3/1 max. Harmonic distortion ≤ %3 THD (Lineer load ) ≤ %6 THD (non-Lineer load) Transfer time Line ↔ battery 0 ms Transfer time Inverter ↔ by-pass 4 ms (tipik) Waveform (Battery mode) Pure sinewave Efficiency Line mode ~ %89 Battery mode ~ %88 Battery Type & number of battery 12V 7Ah x 20 Charge time 5 hours for recharging up to 90% capacity Charge current 1.0 A Charge voltage 273 VDC ± %1 Indicators & Alarm LCD Panel UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, Fault conditions Alarm Battery mode, Low battery, Overload, Fault Dimensions & Weight D x W x H (mm) UPS.580 x 438 x 133 [3U] Battery module.580 x 438 x 133 [3U] Net weight (kg) UPS.17 Battery module.57 Environmental Operating temperature 0-40°C Humidity 20-90% RH (non-condensing) Noise level (audible) < 55 dBA, from 1 m Management Smart RS-232 or USB Windows¨ 98/2000/2003/XP/Vista/2008, Windows¨ 7/8, Linux, MAC SNMP (Optional) Power management from SNMP manager and web browser

TUNCMATIK Newtech Pro Rack Mount Series 6KVA 1/1 Online UPS TSK1814/Rack Mount UPS
GEL 3449
Limited: Call!
<423>

General Properties Product Code TSK1811 EAN Code 8697842802316 Series description Newtech Pro Rack Product description Newtech Pro Rack 1 kVA Capacity / Power 1 kVA / 800 W Display LCD Panel Alarm Battery mode, Low battery, Over load, Error Input Low voltage transfer 160 VAC - %80-100, 140VAC - %70-80, 120 VAC - %60-70, 110 VAC - %0-60 Low voltage correction 170 VAC - %80-100, 150VAC - %70-80, 130 VAC - %60-70, 120 VAC - %0-60 High voltage transfer 300 VAC ± %5 High voltage correction 290 VAC ± %5 Frequency range 40 - 70 Hz Phase 1 Phase + Notr + PE Power factor ≥ 0.99 %100 load Output Output voltage 200/208/220/230/240 VAC Output power factor (PF) 0.8 Voltage regulation battery mode ± %1 Frequency range sync. mode 47-53 Hz or 57-63 Hz Frequency range battery mode 50 ± 0.25 Hz - 60 ± 0.3 Hz Over load line mode %105-110 overload alarm, %110-130 transfer to by-pass in 30sec, %130-150 transfer to by-pass in 1,5sec Over load battery mode %105-110 overload alarm, %110-130 shuts down in 30sec, %130-150 shuts down in 1,5sec Current crest ratio 3/1 max. Harmonic distortion ≤ %2 THD (Lineer load ) ≤ %8 THD (non-Lineer load) Transfer time Line ↔ battery 0 ms Transfer time Inverter ↔ by-pass 4 ms (tipik) Waveform (Battery mode) Pure sinewave Efficiency Line mode ~ %89 Battery mode ~ %86 Battery Type & number of battery 12V 9Ah x 2 Charge time 5 hours for recharging up to 90% capacity Charge current 1.0 A Charge voltage 27.4 VDC Indicators & Alarm LCD Panel UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, Fault conditions Alarm Battery mode, Low battery, Overload, Fault Dimensions & Weight D x W x H (mm) 415 x 440 x 89 [2U] Net weight (kg) 13.2 Environmental Operating temperature 0-40°C Humidity 20-90% RH (non-condensing) Noise level (audible) < 50 dBA, from 1 m Management Smart RS-232 or USB Windows¨ 98/2000/2003/XP/Vista/2008, Windows¨ 7/8, Linux, MAC SNMP (Optional) Power management from SNMP manager and web browser

Tuncmatik Newtech PRO Rack Mount Series 1KVA 1/1 Online UPS TSK1811/Rack Mount UPS
GEL 1109
In stock
<315>

General Properties Product Code TSK1813 EAN Code 8697842802330 Series description Newtech Pro Rack Product description Newtech Pro Rack 1 kVA Capacity / Power 3 kVA / 2400 W Display LCD Panel Alarm Battery mode, Low battery, Over load, Error Input Low voltage transfer 160 VAC - %80-100, 140VAC - %70-80, 120 VAC - %60-70, 110 VAC - %0-60 Low voltage correction 170 VAC - %80-100, 150VAC - %70-80, 130 VAC - %60-70, 120 VAC - %0-60 High voltage transfer 300 VAC ± %5 High voltage correction 290 VAC ± %5 Frequency range 40 - 70 Hz Phase 1 Phase + Notr + PE Power factor ≥ 0.99 %100 load Output Output voltage 200/208/220/230/240 VAC Output power factor (PF) 0.8 Voltage regulation battery mode ± %1 Frequency range sync. mode 47-53 Hz or 57-63 Hz Frequency range battery mode 50 ± 0.25 Hz - 60 ± 0.3 Hz Over load line mode %105-110 overload alarm, %110-130 transfer to by-pass in 30sec, %130-150 transfer to by-pass in 1,5sec Over load battery mode %105-110 overload alarm, %110-130 shuts down in 30sec, %130-150 shuts down in 1,5sec Current crest ratio 3/1 max. Harmonic distortion ≤ %2 THD (Lineer load ) ≤ %8 THD (non-Lineer load) Transfer time Line ↔ battery 0 ms Transfer time Inverter ↔ by-pass 4 ms (tipik) Waveform (Battery mode) Pure sinewave Efficiency Line mode ~ %88 Battery mode ~ %86 Battery Type & number of battery 12V 9Ah x 6 Charge time 5 hours for recharging up to 90% capacity Charge current 1.0 A Charge voltage 82.1 VDC ± %1 Indicators & Alarm LCD Panel UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, Fault conditions Alarm Battery mode, Low battery, Overload, Fault Dimensions & Weight D x W x H (mm) 635 x 440 x 89 [2U] Net weight (kg) 29 Environmental Operating temperature 0-40°C Humidity 20-90% RH (non-condensing) Noise level (audible) < 50 dBA, from 1 m Management Smart RS-232 or USB Windows¨ 98/2000/2003/XP/Vista/2008, Windows¨ 7/8, Linux, MAC SNMP (Optional) Power management from SNMP manager and web browser

Tuncmatik Newtech PRO Rack Mount Series 3KVA 1/1 Online UPS TSK1813/Rack Mount UPS
GEL 2079
In stock
<178>

General Properties Product Code TSK1812 EAN Code 8697842802330 Series description Newtech Pro Rack Product description Newtech Pro Rack 1 kVA Capacity / Power 3 kVA / 2400 W Display LCD Panel Alarm Battery mode, Low battery, Over load, Error Input Low voltage transfer 160 VAC - %80-100, 140VAC - %70-80, 120 VAC - %60-70, 110 VAC - %0-60 Low voltage correction 170 VAC - %80-100, 150VAC - %70-80, 130 VAC - %60-70, 120 VAC - %0-60 High voltage transfer 300 VAC ± %5 High voltage correction 290 VAC ± %5 Frequency range 40 - 70 Hz Phase 1 Phase + Notr + PE Power factor ≥ 0.99 %100 load Output Output voltage 200/208/220/230/240 VAC Output power factor (PF) 0.8 Voltage regulation battery mode ± %1 Frequency range sync. mode 47-53 Hz or 57-63 Hz Frequency range battery mode 50 ± 0.25 Hz - 60 ± 0.3 Hz Over load line mode %105-110 overload alarm, %110-130 transfer to by-pass in 30sec, %130-150 transfer to by-pass in 1,5sec Over load battery mode %105-110 overload alarm, %110-130 shuts down in 30sec, %130-150 shuts down in 1,5sec Current crest ratio 3/1 max. Harmonic distortion ≤ %2 THD (Lineer load ) ≤ %8 THD (non-Lineer load) Transfer time Line ↔ battery 0 ms Transfer time Inverter ↔ by-pass 4 ms (tipik) Waveform (Battery mode) Pure sinewave Efficiency Line mode ~ %88 Battery mode ~ %86 Battery Type & number of battery 12V 9Ah x 6 Charge time 5 hours for recharging up to 90% capacity Charge current 1.0 A Charge voltage 82.1 VDC ± %1 Indicators & Alarm LCD Panel UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, Fault conditions Alarm Battery mode, Low battery, Overload, Fault Dimensions & Weight D x W x H (mm) 635 x 440 x 89 [2U] Net weight (kg) 29 Environmental Operating temperature 0-40°C Humidity 20-90% RH (non-condensing) Noise level (audible) < 50 dBA, from 1 m Management Smart RS-232 or USB Windows¨ 98/2000/2003/XP/Vista/2008, Windows¨ 7/8, Linux, MAC SNMP (Optional) Power management from SNMP manager and web browser

Tuncmatik Newtech PRO Rack Mount Series 2kva 1/1 Online UPS TSK1812/Rack Mount UPS
GEL 1559
Limited: Call!
<289>

დალაგება: 
რაოდენობა: 
ხედვა: